Precautions for parallel use of cables

source:Industry News     Popular:adapter     release time:2021-06-23 10:20:57     Article author:sznbone    

  First of all, for the two power cables used in parallel, it is best to have the same cable model and specification length, so that when the cables are energized, the various parameters of the two power cables are basically close, the current carrying capacity is basically evenly distributed, and there will be no single cable overload. , A large area of fever and burnt phenomenon occurred in advance.

Precautions for parallel use of cables(图1)

  Secondly, the distance between cables running in parallel should be appropriately enlarged, so that when a cable fails, it will not affect the cables used in parallel nearby and burn down at the same time, which reduces the power economic loss of the enterprise to a certain extent.

  Thirdly, power cables run in parallel. The contact and connection status of the wire noses at both ends of the cable and the switch contacts should be checked frequently to ensure that the cable and the switch are well connected, because most of the cables used in parallel are above 35mm, and the conductor resistance per kilometer is Below zero ohms, the magnitude of the resistance is about 10 -1. If the cable nose is not in good contact with the switch, it is easy to cause a certain phase or phases of a cable at the switch to have too large contact resistance, resulting in two cables carrying capacity The distribution is uneven. The current cable customers take into account economy and grid design, and the selection of cable models and specifications will not leave too much current carrying margin. When the contact resistance at the nose of the cable is too large, first, it will heat up in continuous use. Burning out, in addition, causing the current carrying capacity of the two cables to shift, causing one of the cables to be overheated and burned.

  There is another situation worth mentioning, that is, when multi-core armored power cables are used in parallel in the AC grid, the A phase, B phase, and C phase of each cable must be taken out separately and connected with the A, B, and C of the switch respectively. C three-phase parallel connection, it is strictly forbidden to short-circuit all the cores of a cable and connect to one phase of the switch. Because the cable is equivalent to running in a live single-phase, single-phase alternating current will generate eddy currents in the steel strip and cause thermal burn accidents in the cable. In addition, the reduction of the current carrying capacity after parallel connection should be fully considered, and the current carrying capacity after parallel connection is not equal to the current carrying capacity of the actual conductor section.

  Calculation formula for commonly used cable usage in integrated wiring

  1. Demand for RJ-45 headers and information modules

  Demand for RJ-45 head: m=n*4+n*4*15%

  M: Indicates the total demand for RJ-45 connectors

  N: Indicates the total amount of information points

  N*4*15%: indicates the surplus left

  The demand for information modules: m=n+n*3%

  M: Indicates the total demand for information modules

  N: Indicates the total amount of information points

  n*3%: indicates the surplus

  2. Thread consumption per floor

  1. Thread consumption per floor: C=[0.55*(L+S)+6]*n

  L: The farthest information point distance from the management room on this floor

  S: The distance of the information point closest to the management room on this floor

  N: The total number of information points on this floor

  0.55: Spare factor

  6: Termination tolerance

  2. C=[0.55(F+N)+6]*m

  C Thread consumption per floor

  F is the distance from the furthest information socket to the wiring closet

  N is the distance between the nearest information socket and the wiring closet

  m is the number of information sockets on each floor

  3. Number of wire boxes

  1. The longest line distance + shortest line distance) / 2 = average

  (average value + 5 meters) * points = total length

  Total length/305 (standard meters per box) + 2 boxes = total number of boxes

  2. Each service requires a 4-pair unshielded twisted pair cable or 2-core (62.5/125 micron multi-mode) optical cable;

  The total number of horizontal cables in each communication room = (the number of work areas served by the communication room) * (the number of services provided by each work area)

  Calculation of horizontal wiring in work area:

  A: The distance of the closest information point;

  B: the distance of the farthest information point;

  C: The number of information points in each working area

  The required cable length for each layer=(A+B)/2*1.1*C

  The sum of cable lengths of each layer = cable length of each layer * building height

  Total number of required cable boxes = sum of cable lengths of each layer/305 meters

  Remarks: 1.1 The coefficient is the loss, and the floor height is the floor height. If the horizontal trunking runs through the ceiling, it must be calculated; if it is a raised floor, it can be ignored;


Read recommendations:

18-25W Switching Power Supply

MKS-1203000EX Switching Power Supply

24-65W Switching Power Supply

The power supply manufacturer tells you how to solve the interference problem of the power adapter

What is the difference between high-end and low-end power adapters? How to check after playing?

Related Information

What are the unique advantages of high frequency switching power adapter

2022-04-20

General Mechanism Analysis of Switching Power Adapter.ac power adapter wholesaler

2022-04-19

Suppression method of low frequency ripple of switching power supply

2022-04-16

Why is the power adapter making noise?

2022-04-15

When the power adapter is in normal use, what is the normal temperature?

2022-04-14

90% of people use the car charger incorrectly, are you using it right?CAR POWER SUPPLY sales

2022-04-13

The difference between a power adapter and a voltage regulator

2022-04-12

Select the power adapter to determine these three adaptation conditions.SWITCHING POWER Vendor

2022-04-11

Why is the original power adapter better than the non-original one?TRANSFORMER Production

2022-04-09

What are the industries where the power adapter can be applied?CAR CHARGER wholesale

2022-04-08

What is the difference between high-end and low-end power adapters? How to check after playing,CAR P

2022-04-07

How to design a good power adapter,CAR CHARGER wholesaler

2022-04-07

Customized desktop power adapter

2022-04-06

The quality of the switching power supply determines the safety of electricity use,CAR CHARGER whole

2022-04-02

What are the advantages of wireless chargers?

2022-03-30

PD charger is a must-have at home

2022-03-29

What are the main materials of the power adapter shell?

2022-03-26

What is a PD power adapter? It can make charging ubiquitous

2022-03-25

Slow charging? Try a fast charger

2022-03-24

Do you understand the cause of abnormal noise in the power adapter?

2022-03-23

Reasons for abnormal noise of the power adapter

2022-03-22

Talking about the common problems of the power adapter

2022-03-19

General manufacturer power adapter reliability test items

2022-03-18

More energy efficient and safe power adapter

2022-03-17

Five ways to solve the power adapter overheating?

2022-03-16

What are the common connection faults of cottage shared chargers on the market?

2022-03-15

How to use the car charger and matters needing attention!

2022-03-14

Do you know the difference between a power adapter and a charger,CAR CHARGER Processor

2022-03-12

The power adapter has a very wide range of applications,Audio Transformer

2022-03-11

What is the development trend of the power adapter industry,AC ADAPTER

2022-03-10

Popular recommended products

EI-35 ADAPTER AC ADAPTER SWITCHING ADAPTOR Linear Power Adapter Linear Adapter

2020-08-28

MK-C1806028 MKA ADAPTER LINEAR ADAPTOR SWITCHING ADAPTOR Linear Power Adapter Linear Adapter

2020-08-28

ER42 High Frequency Transformer

2020-08-27

500W Charger,Charger

2020-08-28

24W 2USB Charger,24W Charger ,2USB Charger

2020-08-27

12VDC8A 96W power supply

2020-08-28

MKS-1201250HEU Switching Power Supply

2020-08-29

EI-57 ADAPTER LINEAR ADAPTOR Linear Power Adapter Switching Power Adapter INTERCHANGEABLE ADAPTOR Li

2020-08-28

30-500W LED Power Supply 30-500W Power Supply

2020-08-27

12W POWER SUPPLY,12W CAR POWER SUPPLY,POWER SUPPLY,CAR POWER SUPPLY

2020-08-27

36-65W Switching Power Supply

2020-08-29

3-8W Charger,3W Charger,8W Charger,4W Charger,5W Charger,6W Charger,7W Charger

2020-08-27

100-300W Charger,100W Charger,200W Charger,300W Charger

2020-08-27

EI Power Transformer Power Transformer

2020-08-27

12-36W POE POWER SUPPLY

2020-08-27

72-200W Switching Power Supply

2020-08-29

EI-66 ADAPTER LINEAR ADAPTOR SWITCHING ADAPTOR Linear Power Adapter Linear Adapter

2020-08-28

40W 4USB Charger,40W Charger,4USB Charger

2020-08-27

MKS-1203000EX Switching Power Supply

2020-08-29

12W 2USB Charger,2USB Charger,12W Charger,USB Charger

2020-08-27

MKS-1202000-36 Switching Power Supply

2020-08-29

18-25W Switching Power Supply

2020-08-28

12W CAR CHARGER,12W USB CAR CHARGER,CAR CHARGER,12W CHARGER

2020-08-27

3-15W Switching Power Supply

2020-08-28

19V2A 36W Switching Power Supply

2020-08-28

MKA-571652420 ADAPTER AC ADAPTER CE ADAPTOR UL ADAPTOR Linear Adapter

2020-08-28

12V2ASwitching Power Supply

2020-08-28

60W 6USB Charger,60W Charger,6USB Charger,Charger

2020-08-27

MKS-120200EU-36 Switching Power Supply

2020-08-29

24-65W Medical Switching Power Supply

2020-08-27
Copyright 2020 © Merryking Technology Co., Ltd. All rights reserved